1. General Specifications

  • Dimensions:
    • Height: 1350 mm (53.15 inches)
    • Width: 730 mm (28.74 inches)
    • Depth: 820 mm (32.28 inches)
    • Weight: Approximately 135 kg (298 lbs)
  • Power Supply:
    • 100-120 VAC, 50/60 Hz
    • 220-240 VAC, 50/60 Hz
    • Power Consumption: Maximum 250 VA

2. Ventilation System

  • Modes of Ventilation:
    • Volume Control Ventilation (VCV)
    • Pressure Control Ventilation (PCV)
    • Pressure Controlled Ventilation-Volume Guaranteed (PCV-VG)
    • Synchronized Intermittent Mandatory Ventilation (SIMV) with Pressure Support (PS)
    • Pressure Support Ventilation (PSV)
    • Manual ventilation mode
    • Spontaneous breathing with PEEP
  • Tidal Volume Range:  20 to 1500 ml

  • Respiratory Rate: 4 to 100 breaths per minute

  • Inspiratory/Expiratory Ratio (I): 2:1 to 1:8

  • PEEP (Positive End Expiratory Pressure): 0 to 30 cmH₂O

  • Inspiratory Flow Rate: Up to 120 L/min

3. Breathing System

  • Circuit Compliance: Less than 2.5 ml/cmH₂O

  • Fresh Gas Flow: Range: 0 to 15 L/min

    • Mechanical flowmeter for O₂
  • Absorber Capacity: Standard 800 ml soda lime canister

  • Leak Test:

    • Automatic leak testing for the breathing circuit and the machine

4. Patient Monitoring Integration:

  • Anesthesia Gas Monitoring:

    • Integrated gas monitoring for O₂, N₂O, CO₂, anesthetic agents (halothane, isoflurane, sevoflurane, desflurane, enflurane)
  • Pulse Oximetry (SpO₂):

    • Integrated with alarms for desaturation
  • Pressure and Volume Monitoring:

    • Real-time monitoring of airway pressure, tidal volume, and lung compliance
  • EtCO₂ Monitoring:

    • Integrated capnography for continuous end-tidal CO₂ monitoring

5. User Interface & Display

  • Touchscreen Display:

    • High-resolution color touchscreen (15 inches)
    • Customizable interface for different clinical environments
  • Alarms:

    • Visual and audible alarms for all vital parameters
    • Adjustable alarm limits for patient safety
  • Data Connectivity:

    • Connectivity options for hospital networks via Ethernet or wireless
    • USB ports for data transfer and software updates

6. Gas Delivery System

  • Oxygen (O₂) Supply:

    • Low and high pressure O₂ supply
    • Back-up O₂ cylinder holder
  • Nitrous Oxide (N₂O) Delivery:

    • Available with integrated flow meters and safety lock to prevent hypoxia
  • Vaporizer:

    • Dual vaporizer mounting system (selectatec type)

7. Safety Features

  • O₂ Failure Protection:

    • Automatically cuts off N₂O when O₂ pressure drops below a safe threshold
  • Hypoxic Guard:

    • Ensures minimum O₂ concentration when delivering nitrous oxide
  • Alarm System:

    • Comprehensive audio and visual alarms for system failures, gas supply, patient parameters, and more.